RSD-AFCI ICS Plus PV rapid shutdown for SkyBox. Pre-wired with two contactors and six 600Vdc fuse holders, to support three PV strings

$904.07

RSD-AFCI - ICS Plus PV rapid shutdown package for FM100 SystemEdge packages. Compatible with up to six strings of PV source circuits. Includes one FWPV6-FH600-SDA shutdown box, one RSI, and one power supply.  (Fuses sold separately.)

Prefer to checkout with PayPal?

Details

Information

FWPV3-FH600-S2D 

ICS Plus PV rapid shutdown for SkyBox. Pre-wired with two contactors and six 600Vdc fuse holders, to support three PV strings.  Includes cable glands and touch-safe distribution blocks, one ground bus bar and grounding lug. Fuses sold separately.  RSI sold separately.

SKYBOX RAPID SHUTDOWN

Any time a Rapid Shutdown event is triggered, a set of normally-closed terminals on a Rapid Shutdown Initiator will open. When the SkyBox Rapid shutdown input terminals sense this, the SkyBox will shut down accordingly. When this occurs, an Alert message will appear in the SYSTEM NOTIFICATION screen. This shutdown may be limited to the solar portion of the system or it may extend to SkyBox AC input and output.
The extent of the shutdown is selected in the RSD (rapid shutdown response) menu item.
The selections are PV or PV and AC.

When a rapid shutdown event occurs with PV selected, the solar charging is the only portion of the SkyBox shut down.

  • Solar charging is shut down.
  • The S O L A R tile reads WAITING.
  • Grid, load, and other operation continue normally.
  • The Off /On button turns yellow (if previously on). If pressed, the button turns red.
  • All grid, load, and other operations are turned off.
  • The display jumps to the Inverter Fault Status screen.
    NOTE: A fault code will not appear. A Rapid Shutdown initiation is a command given to the SkyBox.
     If the SkyBox was turned off at the time of the shutdown, the O f f /On button will be red. The button will turn yellow if turned on with the shutdown still occurring. NOTE: This behavior will also occur if the Rapid Shutdown terminals are left unconnected.

When a rapid shutdown event occurs with PV and AC selected, all main SkyBox functions are shut down.

  •  Solar charging is shut down. The S O L A R tile reads WAITING.
  •  The SkyBox disconnects from the grid. The G R I D tile reads WAITING.
  •  The inverting function is shut down. The L O A D tile reads OFF.
  •  The O f f /On button remains green (if previously on). If pressed, the button turns gray and all grid, load, and other operation are turned off.
  •  If the SkyBox was turned off at the time of the shutdown, the O f f /On button will be gray. The buttonwill not respond. The SkyBox cannot be turned on until the shutdown is resolved. 
NOTE: This behavior will also occur if the Rapid Shutdown terminals are left unconnected.
Resolving a Rapid Shutdown normally requires simply resetting the Rapid Shutdown Initiator. Other conditions
leading to the shutdown may need to be addressed.

Technical Specifications

SKU FWPV3-FH600-S2D
Weight 15.000000
Manufacturer Outback Power
class 100

Document Library

More from Outback Power
  1. SE-530PLC-SBX
    SE-530PLC-SBX
    $15,396.33
  2. FLEXpower One 3kW 48V Pre-wired FXR Series System 230V
    FLEXpower One 3kW 48V Pre-wired FXR Series System 230V
    $3,181.75
  3. 40 Amp, 150Vdc and 120Vac, 1/4” stud terminals
    40 Amp, 150Vdc and 120Vac, 1/4” stud terminals
    $13.75
  4. 3-shelf comprehensive battery enclosure
    3-shelf comprehensive battery enclosure
    $1,856.25
  5. 175 Amp, 150Vdc, 1/4” stud terminals
    175 Amp, 150Vdc, 1/4” stud terminals
    $75.63
  6. FLEXpower Two 7.2kW 48V Pre-wired FXR Series System 120/240V with 300VDC 100A AFCI CC
    FLEXpower Two 7.2kW 48V Pre-wired FXR Series System 120/240V with 300VDC 100A AFCI CC
    $7,318.44
Leave a review...
You're reviewing: RSD-AFCI ICS Plus PV rapid shutdown for SkyBox. Pre-wired with two contactors and six 600Vdc fuse holders, to support three PV strings
Your Rating